18 Gossen Foto- und Lichtmesstechnik GmbH
5.4 Contrast measuring
in the t and EV functions
Contrast of the subject reflected light
measuring through the viewfinder
- Keep the measuring button M pressed
and focus on the various areas of the subject to be
measured.
- The first measuring value appears on the left digital
display. It is constantly displayed as a reference value
(e.g. measurement on a grey chart) during the course
of the entire measuring process. The actual
measuring value flashes on the analogue scale.
- After releasing the measuring button M, the
measured subject contrast range appears on the
analogue scale.
Illumination contrast
with flat or spherical dome
- Keep the measuring button M pressed to measure
the different light sources.
- The first measuring value appears an the left digital
display. It is constantly displayed as a reference
value (e.g. main light source) during the course of the
entire measuring process. The actual measuring
value flashes on the analogue scale.
- After you release the measuring button M, the total
illumination contrast measured appears on the
analogue scale.