2.4.2.2 Function coding of the function field (FF) in response direction
Bit No. Function Value Meaning
0 ... 2 Reserved 0, 0, 0 (fixed)
3 Request disable 0
1
Instruction executed, equipment ready
Equipment not ready for this instruction, eventually repeat instruction
4 Instruction acknowledgement 0
1
Instruction executed, equipment ready
Instruction could not be executed, equipment ready
5 Transmission error 0
1
Request telegram correct
Request telegram incorrect
6 Not used 0
7 Service request 0
1
None of the errors contained in error status words 1 and 2 occurred
One or more errors occurred, request error status for exact identification!