GOSSEN METRAWATT GMBH 14
2.5 Criteria for the validity of a request telegram
The R2600/01 checks the characters of the telegrams received in accordance with the following tables:
If incorrect values are received for FF, PI and PS, the R2600/01 responds with a short set with set transmission error bit. If the user data is entered
beyond its specific value ranges, the R2600/01 responds with a short set with set service request bit. The bit "impermissible value" is set in the error
status word 2.
If there are other deviations or a parity error, the telegram is invalid, the R2600/01 does not respond.
For short set: For control and long set:
Character No. Criterion Character No. Criterion
1 10h 1 68h
2 Interface address Addr or 255 (see 2.4.2) 2 Note length for PS and end character
3 FF = valid function coding 3 Character 3 = character 2
4 PS = Addr or 255 + FF 4 68h
5 16h 5 Interface address Addr or 255
6 FF = 69h oder 89h
7 PI = valid parameter index (see section 4)
. . . (data block)
Length + 5
PS =
1)
1) Bytewise sum without overflow over all characters from equipment address (Addr or 255) to checksum exclusive
Length + 6 16h