Gossen R2600 User Manual Page 26

  • Download
  • Add to my manuals
  • Print
  • Page
    / 40
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 25
GOSSEN METRAWATT GMBH 26
4.1.2 Unit of the temperature parameters
The unit of the temperature parameters depends upon
the range marking B1 ... B5 of the equipment (see PI = 33h),
the configured sensor type (see PI = 33h) and
the configured unit of the sensor (see PI = 32h).
With standard signal (B2, B5) and Pt100 with 0.1° display, the decimal point only serves for the display on the R26900/01, not for the parameter val-
ues. That is, a value of 234.5 in the display, for example, is to be transmitted as 2345 = 0929. The two characters of the data block then are 29h, 09h.
Marking
Sensor type
0 ... 7 8
B1, B3, B4 1°C / 1°F 0.1°C / 0.1°F
B2, B5 1, 0.1, 0.01, 0.001
Page view 25
1 2 ... 21 22 23 24 25 26 27 28 29 30 31 ... 39 40